P.A.S. PORT® Elite Fluoro-Free® Peripheral Systems with PolyFlow® Polyurethane Catheters
Designed for implantation using the CATH-FINDER® catheter tracking system. The CATH-FINDER® system eliminates the need for fluoroscopy during port implantation. P.A.S.PORT® Systems are designed specifically for arm placement and are still implanted more often than any other peripheral port. Now, you can have the benefits of two materials in one portal. P.A.S. PORT® Elite portals, with plastic on the outside and titanium on the inside, are designed to meet both your clinical needs and your performance demands. Together, plastic and titanium give you benefits neither gives you alone – lightweight patient comfort and long-term durability. P.A.S. PORT® Elite Systems with PolyFlow® Polyurethane Catheters are designed to permit repeated access to the venous system for the parenteral delivery of medications, fluids, and nutritional solutions and for the sampling of venous blood.
Now you can eliminate fluoroscopy during your catheter placement procedures. The CATH-FINDER® catheter tracking system makes Fluoro-Free® catheter placement possible. An innovative technology, the CATH-FINDER® system tracks the catheter tip during the placement procedure without the use of fluoroscopy. A confirming x-ray prior to commencing any therapy is necessary to verify catheter tip location.
Features of port:
- Arm placement of the P.A.S. PORT® Elite Systems is a cosmetically attractive option for many patients
- Its smaller profile is ideal for patients with smaller arms
- Convenient accessing without disrobing
- Plastic portal is lightweight for patient comfort, and has a low profile shape designed for comfortable arm placement
- Allows for a less traumatic implantation procedure
- Minimized risk of immediate insertion complications1
- WIDESITE® septum is designed for large needle puncture area
- Septum is captured in titanium to provide high compression necessary for needle retention and stability
- Titanium portal reservoir provides gouge resistance and long-term durability
- Needle stop titanium reservoir floor creates positive tactile feedback when the accessing needle makes contact
- Beveled front suture holes designed for ease of suturing
- Back pierceable suture hole designed to prevent tissue in-growth
- Nonferrous plastic/titanium portal is compatible with diagnostic imaging, including MRI and CT scanning.
- ULTRA-LOCK® catheter connector for ease of assembly
- Winters V, Peters B, Coila S, Jones L. A trial with a new peripheral implanted vascular access device. Oncology Nursing Forum 1990; 17:891-896
Features of catheter:
- Linder L, Curelaru I, Gustavsson B, et al. Material thrombogenicity in central venous catheterization: A comparison between soft, antebrachial catheters of silicone elastomer and polyurethane. Journal of Parenteral and Enteral Nutrition 1984;8:399-406
Features of the Fluoro-Free® Catheter Placement System:
* CAUTION: The P.A.S. PORT® Elite Fluoro-Free® systems should always be implanted in an appropriately equipped facility, such as an outpatient surgical facility, procedure room, or operating room, in order to manage any complications that might occur.